Measurement specifications
Principle:Electromagnetic
Media range:Liquids (σ>1μS/cm)
Measurement value:Flow speed
Output value:Rate of flow
Accuracy:0.5% ,0.3% or 0.2%
Repeatability:0.16% ,0.1% or 0.06%
Output specifications
Output signal:4-20mA,4-20mA with HART,RS485 or pulse
Power supply:24VDC or 220VAC
Electrical connection
Connection type:Cable gland
Electrical protection
Short circuit:Yes
Reverse polarity:Yes
Material
Body: Carbon steel with painting
Electrode pole: 316LSS,HaC,Titanium,Tantalum,tungsten carbide, Pt Liner: PTFE,FEP,PFA,CR,FVMQ or PU
Environment specifications
Environment temperature:-20 … 85 °C
Media temperature:-40 ... 180℃
Storage temperature:-40 … 70 °C
Ingress protection:(EN 60529) IP67 or IP68
Enviroment humidity:< 98 % RH,without condensation
Process connection
Mounting type:Flange or Sandwich
Flange standard:HG/T 20592 or HG/T 20615
Pipe size:DN3 to DN2000