Why-Winters
中文版 Global sites
Categories
Solid vibrating bar level switch
说明及特点:

Double tube probe design, the first in China;

High detection sensitivity, minimum allowable medium density of 0.02g/cm³,  suitable for most solid particles;

High temperature design, the process temperature can reach 250, and the  ultra-high temperature type (gas/water cooling) process temperature can reach 400, the  industry leading;

Rich self-diagnosis function, can accurately locate fault information;

Effectively prevent hanging, avoid false alarm, simple installation, no need to  calibrate;

The use of strong corrosion resistance materials: 316L, 318S13.

应用范围:

LSF04 vibrating bar level switch is suitable for the measurement of granular solid level,  such as: PVC, sodium hydroxide, lime, cement, sand, soil, coal, dust, flour, sugar, salt,  grain, beans and other materials measurement.

Shell Aluminum :ADC-12 

Ground terminal: 316L 

Sealing element 

Casing and casing cover sea:l silicone 

Process connection 

Thread :316L 

Flange: 316L 

Probe and tube 

Probe: 316L 

Extension tube: 316L 

High temperature extension tube :316L 

Meter weight: 0.8 ~ 4KG 

The measurement frequency is about 360 Hz 

Environmental condition 

The ambient temperature on the shell is -40 ~ 80℃ 

Storage and transport temperature -40 ~ 80℃

Process condition 

Process pressure -1 ~ 16bar 

Process temperature (normal temperature type) -50 ~ 150℃ 

Process temperature (high temperature type) -50 ~ 250℃ 

Process temperature (ultra-high temperature type) -50 ~ 400℃ 

Cooling specifications and parameters (for LSF04 ultra High temperature model  only) 

Cooling inlet pipe 6 x 4 specifications (outer diameter 6mm)PU air pipe 

Cooling pressure 0.8Mpa 

For details about the minimum cooling gas flow, see 5.4 Minimum Cooling Gas Flow 

Sensitivity (minimum measurement density) 

High density >0.05 g/cm³ 

Low density >0.02 g/cm³ 

High-low conversion mode 

High overflow protection 

Low dry operation protection 

Switching delay 

Contact material 0.5s 

No material 1s 

Output mode 

Relay (double pole double throw), two wire system 

Operating voltage 

Relays 20 ~ 250VAC/20 ~ 72VDC 

Switching power 

The minimum is 50mW 

Max. 750 VA AC,54W DC 

Two-wire system 10 ~ 36VDC 

Cable inlet/plug 

Cable inlet M20×1.5, 1/2NPT 

Plug M20×1.5, 1/2NPT

Electrical protection measure 

Protection class IP66/67 

Overvoltage Class III 

Protection class 

Relay I 

Two-wire II 

Explosion-proof certification 

Explosion-proof instruments meet the requirements of relevant domestic  explosion-proof standards. 

Class of protection 

The protection level of this instrument can reach the IP66/67 standard

Tool