Electromagnetic Flowmeter
说明及特点:

Modular functional design, practically for a variety of applications. 

No moving parts in the tube, No wear and tear. 

Easy to choose, easy to install, Maintenance-free and very low operating costs. 

High corrosive resistance; solid and reliable. 

Up to 400: 1 turndown ratio 

Easily achieve the positive cumulative flow, Reverse Cumulative and Difference Calculation. 

Built-in reference electrode, fully guarantee the stability of measurement. 

A variety of IP protection and installation methods, can be install for continuous immersion in water. 

Adopt EEPROM memory to measure operation data, safe and reliable protection of memory.

应用范围:

Environmental protection and water treatment. 

Municipal water supply. 

HVAC Industry 

Food & Beverage and Pharmaceutical. 

Oil & Gas/ Petrochemical 

Fine Chemical

Ambient temperature : -25 - 60 ° C 

Relative humidity : 5% to 90% 

Power supply : Single-phase AC power supply (85 ~ 250) V/ (45 ~ 63) Hz  

                      DC power supply 16VDC ~ 36VDC  

Power consumption : less than 20W

Measurement accuracy:LMF11/LMF11B: 土0.2%,0.5%; LMF12: 土0.5%; LMF13: 土0.5%; LMF14/LMF14B: 土1.5%3. 

Output variables 

1 Analog current output 

• Load resistance : (0-10) mA, (0 -1.5) k Ω, (4-20) mA, (0-750)Ω。 

• Basic error : 0.1% ± 10μ A, 

2 Digital frequency output 

• Frequency output range : (1 ~ 5000) Hz 

• Output Electrical Isolation : Opto-isolated, isolated voltage> 1000V 

• Frequency output drive : FET output, the maximum withstand voltage 36VDC, the maximum load current  of 250mA 

3 Digital pulse output 

• Output pulse range: (0-100) pulse / sec <higher than the upper elbow, will lose pulse> 

• Output pulse equivalent: (0.001-1.000) m³ / cp, 

                                       (0.001-1.000) LTR /cp, 

                                       (0.001-1.000) USG /cp, 

                                       (0.001-1.000) UKG /cp ; 

                                       Output pulse width : User software settings; 

                                       Output Electrical Isolation : Opto-isolated, isolated voltage> 1000V 

                                       Pulse output drive : FET output, the maximum withstand voltage 

                                                                     36VDC, the maximum load current of 250mA 

4 Alarm output

• Alarm output contact : ALMH - upper limit alarm: ALML - lower limit alarm 

• Output Electrical Isolation : Opto-isolated, isolated voltage> 1000V 

• Alarm output drive : transistor output, the maximum withstand voltage of 36V, the maximum load  current of 250mA 

5 Digital communication interface and communication protocol: 

• MODBUS interface • RTU format 

• Physical interface RS-485 

• Electrical isolation 1000V 

• HART interface: support standard HART protocol, configure the HART Communicator, can display the measured value online, and modify the instrument parameters

Tool